YTread Logo
YTread Logo

How to use mix lighting in one room using Dialux evo

How to use mix lighting in one room using Dialux evo
good afternoon everybody never hear again and there's another question from our friend uniess planet horn she said I hi I want to design a

room

that has make slightly such as down lab fellows but my

room

requires three hundred lumen or dreadlocks maybe it's three and Lux so what can I do please kindly let me know okay for you can it I'm not sure if he said 300 lumen or 300 Lux okay because Lubin is from your luminaire and Lux is the last level requirements for some homes so I will just assume that you requires 300 Lux in your

room

and you want a mix of

lighting

all right so let's go and check this sample project that I have right now in my screens so let's go and for example this the

room

that I want so I want to know which one is this

room

yeah meeting

room

let's go for the meeting

room

check this one and select it okay so I selected the meeting

room

now and for example I want to have a 300 Lux for this one so I'll just go to my assessment zone tab just go here assessments on table under your construction tab and then click that wine and then edit and say you want to change it into 300 Lux ok just edit that one and then click on start Lux and your calculation surface is 0.8 okay so let's let's just leave it like that and then you just go and select for example you said you want a mixture of lights so I'll go and for example I I have a square down light here so let's go to the 3ds you can see it I have a square down light here and...
how to use mix lighting in one room using dialux evo
for example you don't like it it's like a heart condition fast and you want to mix it with something else like for example let's just imagine this is a fluorescent lamp I will just for example add i suspended luminaire here plus wall mounted here I can also add some coke like if I like to but my ceiling is not good oh okay I can add here so yeah I can mixed up with say suspended one here at the table and then down lies there and coke like stair and for that and I want to have a 300 Lux on this small meeting

room

okay so let's go now and do it so I'll mix it with suspended wine let's go and check if I have a suspended fitting here I hope I have one okay I have here so I'll just go and drop it here and then this is I think powerful but this is select another one maybe I can have lesser lesser powerful okay okay I'll just use this one the punch let's see it's two by twenty eight one okay it's fluorescent and let's just remove this one and then let's put it in the middle and then let's go and suspend it say 2.2 meters from the floor okay and then now I have suspended one and a down light and if I want to put coke light here I'll go and select if I have LED strip there and let's see so I have flex here yeah very good and I will just run it here later I will just adjust adjust it okay so I will just add maybe ten or twenty pieces of this one okay this is enough think and then on my ceiling i if I want a cone flight and...
how to use mix lighting in one room using dialux evo
I need to adjust my ceiling so I'll go to my ceiling bag that's here adjust it and then I will say offset 0.1 I can see here if I offset it there there will be an edge here for my own sleep okay so let's okay I will just show it to you in life okay now it's here so you can see it's here so I'll just move my LED strip here and okay now it's conscious conf

using

let's go here and rotate that and then move and up and I want if I want that stealing to be yeah I think this is close to the ceiling closed sides yes good good good okay so you cannot see it now because I think my assessment zone height is limited to 2.65 so let's go and check my assessment zone yes it's 2.65 and if I want to make it it's my height for the building yeah extra meter so I'll go and change my assessment zone into three meters so you will see my luminaires when I go into the elevation now it's here you can see because well if you change your height on your assessment zone anything beyond that you will not see it anymore it will it will also not be calculated anymore this is just another tip and tricks okay so let's go and now I have my LED strip at the same time i suspended and my dumb lights let's go and check my LED let's move it a little close here alright so let's go and run it so I'll go to my disk to disk upset calculation tab and I will select fast because I want to just calculate the

room

only this

room

only so let's just...
how to use mix lighting in one room using dialux evo
let's select this one and let's go to the 3d so we can see then let's run it so if you require 300 Lux and if this calculation result shows that it's too much when you either reduce the three things there's just down lights or select lower lumen output from your range okay it's shows that in the meeting

room

this is 594 and on the table it's 9000 sorry 952 this is too much for a meeting

room

it is over lid but for example you are

using

a dolly fitting or you have

lighting

control then it's okay but because you said that you only require 300 Lux so you either remove the down lights and just use a suspended one or just select a lower lumen output for lumen output for everything so for example I will now remove these down lights so let's go and delete it and go to the meeting

room

and recalculate it again and let's see how it goes so but if you want to have down light still in your

room

then select a lower lumen output if that download has 1000 lumen then select at least 600 lumen or whoa okay so you can see this is 267 looks good looks good but because your requirement is 300 Lux then it's not enough so we need to but in your table it's okay because it's 500 Lance already but because you said 300 Lux for overall then I think we need to undo that one and I've to download to download somewhere or let's just select a lower lumen output download just to supply that missing last level so for example let's go to throne...

lighting

go to indoor

lighting

and select at our lives let's just select lower lumen output and for example I will give this sittest LED and I will say I will just just the 9 watt and because this is an office I will select the 4000 Kelvin okay so I'll just use this one and then say yes and then I'll go and click on the right corner now it will be part of my dialogues Evo and I will go to the plan view and lay out this light and for example I want 4 pieces steel but I want to place it a little on the corner and it looks big ok what is the diameter 190 I don't like this one can we select a little smaller smaller download let's check this one ok I have 150 here oh shoot but it's 12 what okay let's just try this one so I will use this 4000 Kelvin and then I will click it and then it's done there and now it's here now in my dialogues so I'll go in apply it here and yes I will put it in the corner so if there are if there is painting on the side it's much better and it's also good for overall uniformity so I just assume it when I drag it there but you can check the distance of from that one okay so let's just check and calculate it and see if we can achieve the tree and relaxed requirements oh okay it's 557 this is again too much so either you just go and add maybe 2 down lights in this corner because maybe there are paintings here and leave it open here or nothing because this is a glass and the light will light from that...
area will be coming from the side of the reception so it's fine so let's just go and maybe remove these two down lights so go ahead select that wine and make it one here oh it's wrong make it one and then this one is what there you go and then just move it here at the corner and then let's run it okay so it's four hundred thirteen lux it's still too much from your requirement which is 300 Lux only so shanem again can it this the solution for that is to either select a low lower lumen output down lights again or maybe this one so instead of this is 2 by 28 maybe you can use 1 by xx only and then for the down light you can select a lower luminal total like for example because this one is 1400 you can go for 900 lumens down light and yeah it can just replace it achieve your own 300 Lux level so the secret for a

room

that has mixed luminaire is by playing with the wattage or the lumen output so even if you have three types of luminaires in your

room

like for example this one you have strip light you have down lights and you have suspended luminaire even a happy even if you have three kinds of luminaire you can still achieve your 300 Lux requirements by selecting luminaires that has lower lumen output like output for everything ok so I hope you enjoyed this tutorial and see you again in the next video like